Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON/Engine Running | |||
Battery Voltage | Data | Volts | 12.6 Volts |
Regulated Voltage Control Current Sensor | Data | % | 0 % |
Starter Switch | Inputs | On/Off | Off |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON/Engine Running | |||
Battery Voltage | Data | Volts | 12.6 Volts |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON/Engine OFF/Transmission in Park | |||
Crank Request Signal | Data | Yes/No | No |
GEN F-Terminal Signal | Data | % | 45% |
GEN L-Terminal Signal Command | Data | On/Off | OFF |
Ignition 1 Signal | Data | Volts | 12.6 Volts |
IMS | Transmission Data | Drive 3, Drive 4\Drive 3, Park\Reverse, Reverse, Drive 3\Drive 2, Drive 2, Park, Invalid, Neutral\Drive 4, Drive 4, Neutral, Reverse\Neutral, Drive 1, Drive 2\Drive 1, Invalid, Open | Park |
Starter Relay Circuit History | Data | OK/Open/Short/Invalid | OK |
Starter Relay Command | Data | On/Off | Off |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Ignition ON/Engine OFF/Transmission in Park | |||
Crank Request Signal | Data | Yes/No | No |
Current Gear | Data | P/N, 1st, 2nd, 3rd, 4th, 5th, Reverse | P/N |
GEN F-Terminal Signal | Data | % | 45 % |
GEN L-Terminal Signal Command | Data | % | 10% |
Ignition 1 Signal | Data | On/Off | Off |
IMS | Transmission Data | Drive 3, Drive 4\Drive 3, Park\Reverse, Reverse, Drive 3\Drive 2, Drive 2, Park, Invalid, Neutral\Drive 4, Drive 4, Neutral, Reverse\Neutral, Drive 1, Drive 2\Drive 1, Invalid, Open | Park |
PNP Switch | Data | Park/Neutral, In Gear | Park/Neutral |
RVS Disable 1 History | Data | None/RPM Too High/Coolant Hot/Crank Abort/EOP Low/Crank Time/MIL On/Backup Timer/APP Too High/Not In Park/VSS Active/VTD Disable | None |
RVS Disable 2 History | Data | None/RPM Too High/Coolant Hot/Crank Abort/EOP Low/Crank Time/MIL On/Backup Timer/APP Too High/Not In Park/VSS Active/VTD Disable | None |
RVS Disable 3 History | Data | None/RPM Too High/Coolant Hot/Crank Abort/EOP Low/Crank Time/MIL On/Backup Timer/APP Too High/Not In Park/VSS Active/VTD Disable | None |
RVS Disable 4 History | Data | None/RPM Too High/Coolant Hot/Crank Abort/EOP Low/Crank Time/MIL On/Backup Timer/APP Too High/Not In Park/VSS Active/VTD Disable | None |
RVS Disable 5 History | Data | None/RPM Too High/Coolant Hot/Crank Abort/EOP Low/Crank Time/MIL On/Backup Timer/APP Too High/Not In Park/VSS Active/VTD Disable | None |
RVS Disable 6 History | Data | None/RPM Too High/Coolant Hot/Crank Abort/EOP Low/Crank Time/MIL On/Backup Timer/APP Too High/Not In Park/VSS Active/VTD Disable | None |
RVS Disable 7 History | Data | None/RPM Too High/Coolant Hot/Crank Abort/EOP Low/Crank Time/MIL On/Backup Timer/APP Too High/Not In Park/VSS Active/VTD Disable | None |
RVS Disable 8 History | Data | None/RPM Too High/Coolant Hot/Crank Abort/EOP Low/Crank Time/MIL On/Backup Timer/APP Too High/Not In Park/VSS Active/VTD Disable | None |
Starter Relay Command | Data | On/Off | Off |