Tools Required
• | J 5403 Internal Snap
Ring Pliers |
- Recover the refrigerant using the J 39500-B
.
- Disconnect the electrical connector from the switch (3 or 4) in
the rear head of the compressor.
- Remove the switch retaining ring using the J 5403
.
- Remove the switch (3 or 4) from the compressor.
Notice: If the existing switch will be reinstalled in the compressor, a new
O-ring seal must be used and preferably a new retainer should also be used.
A new switch kit has the O-ring and retainer ring included.
- Remove the old O-ring seal from the switch cavity using the J 9553-01
.