The numbers below refer to the step numbers on the diagnostic table.
The specified values are from the A/C System Performance Test.
The voltage will vary between 0-12 volts during normal operation. The HVAC control module connector must be connected during this step.
Step | Action | Values | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted, or the cooling is insufficient during A/C operation. | ||||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information | ||||||||||
2 |
Does the blower motor operate in any of the speed positions? | -- | Go to Step 3 | Go to Blower Motor Inoperative | ||||||||||
3 | Does the blower motor operate at the desired speeds? | -- | Go to Step 4 | Go to Blower Motor Malfunction | ||||||||||
4 | When the A/C is ON, does the customer concern occur? | -- | Go to Step 5 | Go to Step 7 | ||||||||||
5 |
Does the recirculation door move to the recirculation position? | -- | Go to Step 6 | Go to Air Delivery Improper | ||||||||||
6 |
Does the A/C compressor operate? | -- | Go to Step 7 | |||||||||||
Perform the refrigerant system performance test. Refer to Air Conditioning (A/C) System Performance Test in Heating, Ventilation and Air Conditioning. Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 8 | |||||||||||
8 |
Does the air temperature actuator drive shaft rotate at all? | -- | Go to Step 9 | Go to Step 10 | ||||||||||
9 | Inspect the air temperature door and the air temperature actuator for the following conditions:
Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 10 | ||||||||||
10 | Test the ignition 3 voltage circuit of the suspect air temperature actuator for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 11 | ||||||||||
11 | Test the ground circuit of the suspect air temperature actuator for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 12 | ||||||||||
12 | Test the suspect air temperature door control circuit of the air temperature actuator for the following:
Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 13 | ||||||||||
13 | Test the ignition 3 voltage circuit of the HVAC control module for the following:
Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 14 | ||||||||||
14 | Test the ground circuit of the HVAC control module for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 15 | ||||||||||
Important: The HVAC control module connector must be connected to correctly perform this test.
Does the voltage measure within the specified values with a smooth transition between COLD and HOT? | 0-12 V | Go to Step 17 | Go to Step 16 | |||||||||||
16 | Inspect for poor connections at the harness connector of the suspect air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 18 | ||||||||||
17 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 19 | ||||||||||
18 | Replace the suspect air temperature actuator. Refer to Air Temperature Actuator Replacement - Right Side or Air Temperature Actuator Replacement - Left Side . Did you complete the replacement? | -- | Go to Step 20 | -- | ||||||||||
19 | Replace the HVAC control module. Refer to Control Module References in Computer/Integrating Systems for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 20 | -- | ||||||||||
20 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |