The SIR Scan Tool Data Definitions contain a brief description
of all SIR related parameters available on the scan tool. The following list
is in the order that the list appears on the scan tool.
Ignition 1: The scan tool displays 0-25.5 volts. The ignition
represents the system voltage measured by the SDM at the ignition feed.
Driver Senselo: The scan tool displays 0-20 volts. The SDM measures
the voltage of the driver low terminal voltage and displays the voltage as
Driver Senselo.
Passenger Senselo: The scan tool displays 0-20 volts. The SDM measures
the voltage of the passenger low terminal voltage and displays the voltage
as Passenger Senselo.
Dr. Bag Energy Reserve: The scan tool displays 0-30 volts. The SDM measures
the voltage of the driver energy reserve capacitors inside the SDM and displays
the voltage as Driver Energy Reserve.
Pass Bag Energy Reserve: The scan tool displays 0-30 volts. The SDM measures
the voltage of the passenger energy reserve capacitors inside the SDM and
displays the voltage as Passenger Energy Reserve.
Lamp Continuous on Time: The scan tool displays 0-182 hours. The SDM measures
the continuous warning lamp ON time.
Ignition cycles lamp ON: The scan tool displays 0-125 cycles. The ignition
cycles with the warning lamp ON.
Ign. cycles lamp Off: The scan tool displays 0--125 cycles. The ignition
cycles with the warning lamp OFF.
Driver VDIF: The scan tool displays 0-500 millivolts. The SDM measures
the difference between driver high and driver low in order to determine voltage
differential.
Passenger VDIF: The scan tool displays 0-500 millivolts. The SDM measures
the difference between passenger high and driver low terminals in order to
determine voltage differential.
Seatbelt Status: The scan tool displays Buckled or Unbuckled. A serial data message
received by the SDM from the body control module (SBM) representing
seat belt status.