The Sensing and Diagnostic Module (SDM) learns the source ID of the battery voltage report message. The SDM monitors this message every 300 milliseconds.
The SDM monitors the Class 2 serial data line during CONTINUOUS MONITORING for the battery voltage report.
The battery voltage report indicates the battery voltage is above 15.5 volts.
The SDM sets DTC B1328 and disables the State Of Health (SOH) DTCs U1064, U1096, U1255, U1300, and U1301.
The SDM receives a battery voltage report message that the battery voltage is below 15.5 volts.
Refer to Charging System Check to diagnose a overcharging condition.