The heater-A/C control determines the amount of sunlight produced by the sun through an input from the sun load temperature sensor. The heater-A/C control receives a voltage signal from the sun load temperature sensor through circuit 590 (LT BLU/BLK). The sun load temperature sensor is grounded by the heater-A/C control through circuit 61 (YEL).
As the sunlight increases, the electric current flowing through the sun load temperature sensor increases. When the heater-A/C control is in AUTO mode, it uses the sun load temperature sensor information to control the blower speed and BI-LEVEL modes.
The heater-A/C control performs a check on the operation of the sun load temperature sensor and detects an open in circuit 590 (LT BLU/BLK).
The heater-A/C control stores DTC B0348 in memory.
• | An open in circuit 590 (LT BLU/BLK) is no longer present. |
• | Under all fault conditions, the ignition switch must be cycled from on to off, back to on before this DTC can change from current to history. |
• | A history DTC clears after 100 drive cycles if a short to ground in circuit 590 (LT BLU/BLK) is no longer present. |
• | Using a scan tool. |
The following conditions may cause this DTC to set:
• | A poor connection or open in circuit 590 (LT BLU/BLK). |
• | A poor connection or open in circuit 61(YEL). |
• | A faulty sun load temperature sensor. |
• | A faulty heater-A/C control. |
The number(s) below refer to the step number(s) on the diagnostic table.
This step checks for proper voltage value at the sun load temperature sensor.
This step checks for a short to ground in 590 (LT BLU/BLK) .
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the heater-A/C control diagnostic system check performed? | -- | Go to Step 2 | Go to Diagnostic System Check |
Is the measured voltage within the specified range? | 4.5-5.5V | Go to Step 3 | Go to Step 4 | |
3 | Check the sun load temperature sensor connector for poor terminal contact. Replace the sun load temperature sensor if the connection is OK. Refer to Sun Load Sensor Replacement . Is the repair complete? | -- | System OK | -- |
Is the measured resistance same as the specified value? | ∞ | Go to Step 6 | Go to Step 5 | |
5 | Locate and repair a short to ground in circuit 590 (LT BLU/BLK) . Is the repair complete? | -- | System OK | -- |
6 | Replace the heater-A/C control. Refer to Control Assembly Replacement . Is the repair complete? | -- | System OK | -- |