Tools Required
Removal Procedure
- Remove the condenser tube. Refer to
Condenser Tube Replacement
.
- Use J 26549-E
in order
to remove the expansion (orifice) tube.
Important: DO NOT use any solvents or chemicals to clean the porous plastic inlet
filter of the expansion (orifice) tube .
- Inspect the expansion (orifice) tube for the following conditions and
clean or replace with a new tube as indicated:
• | Broken plastic frame (1); replace the tube. |
• | Inlet filter (3) damaged or plugged with fine gritty material;
replace the tube. |
• | Inlet filter (3) coated with metal chips, flakes, or slivers;
remove the coating with low pressure shop air ONLY and reuse if the filter
is cleaned satisfactorily. Do NOT reuse the O-ring seals (2). |
Installation Procedure
Important: Lubricate the new O-ring seal (2) with mineral base 525 viscosity
refrigerant oil.
- If you reuse the orifice tube, install the new O-ring seals (2).
- Carefully grasp the edge of the expansion (orifice) tube (1)
without touching the inlet filter (3) and insert the expansion tube
into the condenser tube until fully seated.
- Install the condenser tube. Refer to
Condenser Tube Replacement
.
- Leak test the fittings of the component using J 39400-A
.