Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the HVAC Blower Controls System Check? | -- | Go to Step 2 | |
2 | Replace the blower motor relay with a known good relay. Does the blower motor operate correctly? | -- | Go to Step 3 | Go to Step 4 |
3 | Replace the blower motor relay. Is the repair complete? | -- | -- | |
4 |
Does the test lamp light? | -- | Go to Step 5 | Go to Step 6 |
5 | Repair the short to battery positive in CKT 52 between the heater A/C control assembly connector C1 terminal C and the underhood wiring harness junction block connector C3 terminal D9. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 |
Does the test lamp light? | -- | Go to Step 7 | Go to Step 8 |
7 | Replace the underhood wiring harness junction block. Is the repair complete? | -- | -- | |
8 |
Does the test lamp light? | -- | Go to Step 9 | Go to Step 10 |
9 | Repair the short to positive battery voltage in CKT 65 between the underhood wiring harness junction block and the blower motor connector. Is the repair complete? | -- | -- | |
10 | Replace the heater A/C control assembly. Refer to Control Assembly Replacement . Is the repair complete? | -- | -- |