GM Service Manual Online
For 1990-2009 cars only

Application

Specification

Metric

English

Battery Usage

  • Cold Cranking (Apms)

525

  • Delco Replacement Number

48/91-60

  • Reserve Capacity (Amps)

110

  • Test Load (AMPS)

250

Starter Solenoid Test

  • No Load Test at 11.5 Volts
  • Current Draw

75 Amps

Generator

  • Brush Legth (Min.)

8.00 mm

0.315 in

  • Commutator Diameter (Min.)

31.20 mm

1.225 in

Generator Usage

  • Rated Ouput (AMPS)

120

  • Type

Bosch