Step
| Action
| Value(s)
| Yes
| No
|
1
| Was the Charging System Check performed?
| --
|
Go to Step 2
| Go to
Charging System Check
|
2
|
- Disconnect generator connector C2.
- Turn the ignition switch to the ON position.
Is the charging indicator lamp illuminated?
| --
|
Go to Step 4
|
Go to Step
3
|
3
| Repair or replace the generator. Refer to
Generator Replacement
in Engine Electrical.
Is the repair or replacement complete?
| --
|
Go to Step 7
| --
|
4
| Disconnect connector C102.
Is the charging indicator lamp illuminated?
| --
|
Go to Step 6
|
Go to Step
5
|
5
|
- Locate the short to ground in circuit PM1 between the generator
connector C2 and connector C102 terminal 3.
- Repair the short to ground in circuit PM1.
Is the repair complete?
| --
|
Go to Step
7
| --
|
6
|
- Locate a short to ground in circuit PM1 between the gauge cluster
connector terminal 18 and connector C102 terminal 3.
- Repair the short to ground in circuit PM1 between the gauge cluster
connector terminal 18 and connector C102 terminal 3.
- Replace the gauge cluster if circuit PM1 is OK. Refer to
Voltage/Oil Gauge Replacement
in
Instrument Panel, Gauges and Console.
Is the repair or replacement complete?
| --
|
Go to Step 7
| --
|
7
|
- Connect all connectors and components that were disconnected.
- Verify that the charging indicator lamp operates properly.
Does the charging indicator lamp operate properly?
| --
| System OK
|
Go to Step 1
|