Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |
2 |
Is the Fasten Seat Belt lamp illuminated? | -- | Go to Step 3 | Go to Step 4 |
3 | Test the seat belt switch ground circuit for an open. Refer to Testing for Continuity in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 5 | Go to Step 6 |
4 | Replace the seat belt switch. Did you complete the replacement? | -- | Go to Step 5 | -- |
5 | Verify the operation of the Fasten Seat Belt lamp. Is the Fasten Seat Belt lamp operating properly? | -- | System OK | -- |
6 | Test the seat belt switch signal circuit for an open (CKTs XF20 and XF21). Did you find and correct the condition? | -- | Go to Step 5 | Go to Step 7 |
7 |
Did you find and correct the condition? | -- | Go to Step 5 | Go to Step 8 |
8 | Replace the gauge cluster. Did you complete the replacement? | -- | Go to Step 9 | -- |
9 | Test the gauge cluster functions. Do all gauge cluster functions operate properly? | -- | System OK | -- |