Step
| Action
| Value(s)
| Yes
| No
|
1
| Was the Instrument Cluster Diagnostic System Check performed?
| --
|
Go to Step 2
| Go to
Diagnostic System Check - Instrument Cluster
|
2
|
- Disconnect the engine oil level sensor connector.
- Drive the vehicle for approximately half a mile.
Is the indicator lamp ON?
| --
|
Go to Step 3
|
Go to Step 4
|
3
| Replace the engine
oil level sensor.
Is the replacement complete?
| --
|
Go to Step 5
| --
|
4
|
- Check for a short to ground in CKTs XU4 and XU600.
- If OK, replace the gauge cluster.
Is the repair or replacement complete?
| --
|
Go
to Step 5
| --
|
5
|
- Connect all connectors and components that were removed in previous
steps.
- Verify that the low engine oil level indicator operates properly.
Does the low engine oil level indicator operate properly?
| --
| System OK
|
Go to Step 2
|