Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the BCM Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check - Body Control System in Body Control System |
2 |
Does the scan tool display ON? | -- | Go to Step 3 | Go to Step 4 |
3 |
Was a problem found with the above circuits? | -- | Go to Step 5 | Go to Step 6 |
4 |
Is the measured resistance less than the specified value? | .5 ohms | Go to Step 6 | Go to Step 7 |
5 | Repair the intermittent circuit malfunction or replace the door lock switch. Refer to Doors. Is the repair or replacement complete? | -- | Go to Step 12 | -- |
6 |
Is the replacement complete? | -- | Go to Step 12 | -- |
7 |
Does the scan tool display ON? | -- | Go to Step 8 | Go to Step 9 |
8 | Replace the door lock switch. Refer to Doors. Is the replacement complete? | -- | Go to Step 12 | -- |
9 | Remove the jumper wire end from terminal 1 and connect it to a known good ground. Does the scan tool display ON? | -- | Go to Step 10 | Go to Step 11 |
10 |
Is repair complete? | -- | Go to Step 12 | -- |
11 |
Is the repair complete? | -- | Go to Step 12 | -- |
12 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | -- |