Caution: Gasoline or gasoline vapors are highly flammable. A fire could occur
if an ignition source is present. Never drain or store gasoline or diesel
fuel in an open container, due to the possibility of fire or explosion. Have
a dry chemical (Class B) fire extinguisher nearby.
Caution: Wrap a shop towel around the fuel pressure connection in order to reduce
the risk of fire and personal injury. The towel will absorb any fuel leakage
that occurs during the connection of the fuel pressure gage. Place the towel
in an approved container when the connection of the fuel pressure gage
is complete.
Notice: Clean all of the following areas before performing any disconnections
in order to avoid possible contamination in the system:
• | The fuel pipe connections |
• | The areas surrounding the connections |
- Install the J 42242
to the fuel pressure service connection at the rear of the
upper intake plenum.
- Install the J 34730-1A
to the J 42242
.
- Turn ON the ignition.
Caution: Do not drain the fuel into an open container. Never store the fuel in
an open container due to the possibility of a fire or an explosion.
- Place the
bleed hose of the fuel pressure gage into an approved gasoline container.
- Open the bleed valve on the fuel pressure gage in order to bleed
the air from the fuel pressure gage.
- Command the fuel pump ON with a scan tool.
- Close the bleed valve on the fuel pressure gage.
- Inspect for fuel leaks.