Removal Procedure
- Remove the transmission oil pan and oil filter. Refer to
Changing Fluid and Oil Filter .
- Disconnect the electrical connector from the solenoid valve.
- Remove the retaining pin (2). Use pliers to pull the pin out.
- Remove the solenoid (1).
- Remove the solenoid valve and the wave washer.
Installation Procedure
- Install the solenoid valve (1) and the wave washer.
- Install the retaining pin (2). Use a soft mallet to drive the pin in.
- Connect the electrical connector to the solenoid valve.
- Install the transmission oil filter and the transmission oil pan. Refer to
Changing Fluid and Oil Filter .
Important: It is recommended that transmission adaptive pressure (TAP) information be reset.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM, PCM or TCM will
need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.
- Reset the TAP values. Refer to
Adapt Function.