Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Power Window Schematics | |||
1 | Did you review the Power Windows Description and Operation? | Go to Step 2 | Go to Symptoms - Doors |
2 | Verify that the inoperative power windows lockout function fault is present. Does the power windows lockout function operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 4 |
4 | Inspect for poor connections at the LH door switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 7 | Go to Step 6 |
5 | Repair the short to voltage in the power window master switch lockout signal circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 7 | -- |
6 | Replace the LH door switch. Refer to Power Accessory Switch Panel Replacement . Did you complete the repair? | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |