Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Did you perform the Remote Keyless Entry Diagnostic System Check? | -- | ||||||
2 | Is the remote keyless entry system inoperative from both transmitters? | -- | Go to Step 3 | Go to Step 4 | ||||
3 | Reprogram the transmitters. Refer to Transmitter Programming . Do the transmitters now operate? | -- | Go to Step 5 | |||||
4 |
Does the transmitter operate? | -- | Go to Step 10 | |||||
5 |
Is the voltage within the specified range? | 10 -15 V | Go to Step 7 | Go to Step 6 | ||||
6 | Repair the open or short to ground in CKT 2640 (ORN). Is the repair complete? | -- | -- | |||||
7 | Measure the voltage between the following RFA module connectors:
Is the voltage within the specified range? | 10 -15 V | Go to Step 9 | Go to Step 8 | ||||
8 | Repair the open in CKT 1051 (BLK). Is the repair complete? | -- | -- | |||||
9 | Replace the RFA module. Refer to Remote Control Door Lock Receiver Replacement . Is the repair complete? | -- | -- | |||||
10 | Replace the transmitter. Refer to Transmitter Replacement . Is the repair complete? | -- | -- |