Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Lighting Systems Diagnostic System Check? | Go to Step 2 | |
2 |
Does the vanity lamp illuminate? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp lluminate? | Go to Step 4 | Go to Step 5 |
4 | Connect a test lamp between the feed circuit of the inoperative vanity lamp and the ground circuit of the inoperative vanity lamp Does the test lamp illuminate? | Go to Step 7 | Go to Step 6 |
5 | Repair the open in the feed circuit of the vanity lamp. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 9 | -- |
6 | Repair the open in the ground circuit of the vanity lamp. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 9 | -- |
7 | Inspect for poor connections at the connector of the vanity lamp. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 9 | Go to Step 8 |
8 | Replace the vanity lamp. Refer to Vanity Mirror Lamp Replacement . Did you complete the replacement? | Go to Step 9 | -- |
9 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |