Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Lighting Systems Diagnostic System Check? | ||
2 | Disconnect the hazard switch Are the hazard lamps on? | ||
3 | Test the hazard input circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | ||
4 | Inspect for poor connections at the turn/hazard flasher module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | ||
5 | Replace the turn/hazard flasher module. Refer to Hazard and Turn Signal Flasher Replacement Did you complete the replacement? | -- | |
6 | Inspect for poor connections at the hazard switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | ||
7 | Replace the hazard switch assembly. Refer to Hazard Warning Switch Replacement . Did you complete the replacement? | -- | |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK |