Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform A Diagnostic System Check - Theft Deterrent? | -- | Go to Step 2 | |
2 |
Does the SECURITY indicator illuminate during the bulb check? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Replace the instrument cluster (IPC). Refer to Instrument Cluster Replacement In Instrument Panel, Gauges and Console. Did you complete the replacement? | -- | Go to Step 4 | -- |
4 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |