Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Has the Garage Door Opener System Check been performed? | -- | ||
2 | Press any button on GDO. Does the LED illuminate? | -- | ||
3 | Inspect the valet switch. Is the valet switch in the OFF position? | -- | ||
4 | Inspect the GDO for being fully seated in the overhead console. Is the GDO installed properly? | -- | ||
5 |
Is the voltage within the specified range? | 10 - 15 Volts | ||
6 | Using a DMM inspect the garage door opener switch, terminal 1 for ground. Is a ground present? | -- | ||
7 | Inspect for battery voltage from C1 terminal B5 of the Body Control Module (PZM) to ground. Is voltage within the specified range? | 10 - 15 Volts | ||
8 | Inspect for voltage from terminal A of the Valet Switch to B+. Is voltage within the specified range? | 10 - 15 Volts | ||
9 | Inspect for open in CKT 151 (BLK/WHT) from valet switch terminal A to G205. Is repair complete? | -- | -- | |
10 | Turn valet switch to the ON position. Is repair complete? | -- | -- | |
11 | Replace Garage Door Opener. Refer to Roof Console Replacement . Is repair complete? | -- | -- | |
12 | Replace overhead console. Refer to Roof Console Replacement Is repair complete? | -- | -- | |
13 | Remove overhead console. Refer to Roof Console Replacement Assure the GDO is fully seated and making proper electrical connection to overhead console harness. Is repair complete? | -- | -- |