This DTC tests the evaporative emission (EVAP) system for a small leak. The control module monitors the fuel tank pressure (FTP) sensor signal to determine the vacuum decay rate. At an appropriate time, the control module turns the EVAP canister purge valve ON and the EVAP vent valve ON. This allows the engine to draw a vacuum on the EVAP system. At a calibrated time, or vacuum level, the control module turns the EVAP canister purge valve OFF, sealing the system, and monitors the FTP sensor input in order to determine the EVAP system vacuum decay. If the control module detects a leak larger than a calibrated amount, this DTC sets.
The following table illustrates the relationship between the ON and OFF states, and the Open or Closed states of the EVAP canister purge and vent valves.
Control Module Command | EVAP Canister Purge Valve | EVAP Canister Vent Valve |
---|---|---|
ON | Open | Closed |
OFF | Closed | Open |
• | DTCs P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0121, P0122, P0123, P0125, P0440, P0443, P0449, P0452, P0453, P1106, P1107, P1111, P1112, P1114, P1115, P1121 and P1122 not active. |
• | The ignition voltage is between 10-18 volts. |
• | The barometric pressure (BARO) is more than 75 kPa. |
• | The fuel level is between 15-85 percent. |
• | The engine coolant temperature (ECT) is between 4-30°C (39-86°F). |
• | The intake air temperature (IAT) is between 4-30°C (39-86°F). |
• | The start up ECT and IAT are within 9°C (16°F) of each other. |
The EVAP system can achieve vacuum, but a vacuum decay is detected during the diagnostic test.
• | The control module stores the DTC information into memory when the diagnostic runs and fails. |
• | The malfunction indicator lamp (MIL) will not illuminate. |
• | The control module records the operating conditions at the time the diagnostic fails. The control module stores this information in the Failure Records. |
• | The driver information center, if equipped, may display a message. |
• | A current DTC Last Test Failed clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other non-emission related diagnostic. |
• | Clear the DTC with a scan tool. |
To aid in locating intermittent leaks, use the J 41413 EVAP Pressure/Purge Diagnostic Station to pressurize the EVAP system. Move all EVAP components while testing with the J 41416 Ultrasonic Leak Detector.
The numbers below refer to the step numbers on the diagnostic table.
This step verifies that a failure condition is present.
This step verifies that the leak has been repaired.
Step | Action | Values | Yes | No | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Evaporative Emissions Hose Routing Diagram | ||||||||||||||||||||||||
1 | Did you perform the Diagnostic System Check-Engine Controls? | -- | Go to Step 2 | |||||||||||||||||||||
2 | Does the scan tool indicate DTC P0443 or DTC P0449 are also set? | -- | Go to Step 3 | |||||||||||||||||||||
3 |
Did you find and correct the condition? | -- | Go to Step 6 | Go to Step 4 | ||||||||||||||||||||
Important: Always zero the EVAP pressure and vacuum (in H2O) gages on the EVAP pressure/purge diagnostic station before proceeding with diagnosis.
Does the EVAP system pressure remain constant? | 5 in H2O | Go to Diagnostic Aids | Go to Step 5 | |||||||||||||||||||||
5 |
Important: It may be necessary to partially lower the fuel tank to inspect components located in the upper portion of the tank.
Did you find and correct the condition? | 15 in H2O | Go to Step 6 | Go to Diagnostic Aids | ||||||||||||||||||||
Does the EVAP system pressure remain constant? | 5 in H2O | Go to Step 7 | Go to Step 2 | |||||||||||||||||||||
7 |
Does the DTC run and pass? | -- | Go to Step 8 | Go to Step 2 | ||||||||||||||||||||
8 | With a scan tool, observe the stored information, Capture Info. Does the scan tool display any DTCs that you have not diagnosed? | -- | System OK |