Battery Voltage: The scan tool displays 0-20 Volts. The scan tool
displays the voltage as received on the battery positive voltage circuit of
the Module or the 72-08 battery voltage message from the BCM over class
2 lines.
Crank Request Signal: The scan tool displays Yes/No. The scan tool displays No until
the ignition is placed into the START position then Yes is displayed.
GEN F-Terminal Signal: The scan tool displays 0%-100%. The scan tool displays 0%-10% until
the engine is started and the PCM receives a signal from the generator then
OK is displayed.
GEN L-Terminal Signal Command: The scan tool displays On/Off. The scan tool displays Off until
the engine is running, then the PCM supplies a 5 volt reference signal for
the generator regulator.
IMS: The scan tool displays Park, Park/Reverse, Reverse, Reverse/Neutral,
Neutral, Neutral/Drive 4, Drive 4, Drive 4/Drive 3, Drive 3, Drive 3/Drive
2, Drive 2, Drive 2/Drive 1, Drive 1. The scan tool displays the physical
position of the Automatic Transaxle Fluid Pressure Manual Valve Position Switch,
Including those positions that are in-between gears.
Ignition 1 Signal: The scan tool displays 0-20 Volts. The scan tool displays
the voltage as received on the Ignition 1 circuit to the PCM.
Starter Relay Command: The scan tool displays ON/OFF. The scan tool displays Off until
the ignition is placed into the Start position, then it reads On until an
engine run signal is received by the PCM.