Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 4 | Go to Step 3 | |||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK | Go to Symptoms - HVAC Systems - Automatic in HVAC Automatic |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-18°C (55-65°F) | 0-100% | 165-207 kPa (24-30 psi) | 1089-1296 kPa (158-188 psi) | 9°C (49°F) |
19-24°C (66-75°F) | Below 40% | 172-214 kPa (25-31 psi) | 1151-1358 kPa (167-197 psi) | 10°C (50°F) |
Above 40% | 193-234 kPa (28-34 psi) | 876-1083 kPa (127-157 psi) | 12°C (53°F) | |
25-29°C (76-85°F) | Below 35% | 172-214 kPa (25-31 psi) | 1020-1227 kPa (148-178 psi) | 11°C (51°F) |
35-60% | 179-221 kPa (26-32 psi) | 1007-1214 kPa (146-176 psi) | 11°C (52°F) | |
Above 60% | 228-269 kPa (33-39 psi) | 1255-1462 kPa (182-212 psi) | 14°C (57°F) | |
30-35°C (86-95°F) | Below 30% | 207-248 kPa (30-36 psi) | 1110-1317 kPa (161-191 psi) | 13°C (55°F) |
Above 30% | 228-269 kPa (33-39 psi) | 1193-1400 kPa (173-203 psi) | 14°C (58°F) | |
36-41°C (96-105°F) | Below 20% | 207-262 kPa (31-41 psi) | 1255-1531 kPa (182-222 psi) | 14°C (57°F) |
20-40% | 214-296 kPa (33-43 psi) | 1310-1586 kPa (190-230 psi) | 15°C (59°F) | |
Above 40% | 248-317 kPa (36-46 psi) | 1351-1627 kPa (196-236 psi) | 17°C (62°F) | |
42-46°C (106-115°F) | Below 20% | 255-324 kPa (37-47 psi) | 1503-1779 kPa (218-258 psi) | 17°C (63°F) |
Above 20% | 310-379 kPa (45-55 psi) | 1538-1813 kPa (223-263 psi) | 22°C (71°F) | |
47-49°C (116-120°F) | Below 30% | 345-414 kPa (50-60 psi) | 1800-2075 kPa (261-301 psi) | 24°C (75°F) |