The HVAC control processor commands the right air temperature actuator to move by controlling the voltage supplied on the control circuit. A low voltage of 0 volts moves the door toward full hot. A voltage of 2.5 volts stops the door. A high voltage of 5 volts moves the door toward full cold. The HVAC control processor determines the current position of the actuator by monitoring the voltage on the signal circuit. The feedback potentiometer is a function of the motor position. A high voltage of 4-5 volts indicates full cold door position. A low voltage of less than 1 volt indicates full hot door position. The HVAC control processor controls the door positions of the right air temperature actuator in order to maintain the selected air temperature.
The ignition is turned ON.
The HVAC control processor detects the signal circuit is less than 5 counts (0.09 volts) or greater than 250 counts (4.90 volts).
The HVAC control processor uses a default value for the sensor data in order to maintain the air temperature that is selected by the driver.
• | The DTC will become history if the HVAC control processor no longer detects a condition. |
• | The history DTC clears after 50 fault free ignition cycles. |
• | The DTC can be cleared with a scan tool. |
Test the following conditions:
• | A door that is disconnected or broken may also set this DTC, by allowing the right air temperature actuator to travel to the internal stops. |
• | If the condition is not present, refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. |
The numbers below refer to the step numbers on the diagnostic table.
Tests for the proper operation of the circuit in the high voltage range.
Tests for the proper operation of the circuit in the low voltage range. If the fuse in the jumper opens when you perform this test, the signal circuit is shorted to voltage.
Tests for a short to ground in the 5 volt reference circuit.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics | ||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Is the Act Pass. Mix Door Pos. parameter within the specified range? | 5-250 counts | Go to Diagnostic Aids | Go to Step 3 |
Is the Act Pass. Mix Door Pos. parameter greater than the specified value? | 250 counts | Go to Step 4 | Go to Step 8 | |
Is the Act Pass. Mix Door Pos. parameter less than the specified value? | 5 counts | Go to Step 5 | Go to Step 9 | |
Is the Act Pass. Mix Door Pos. parameter greater than the specified value? | 250 counts | Go to Step 7 | Go to Step 6 | |
6 | Test the 5 volt reference circuit of the right air temperature actuator for a short to ground. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 12 |
7 | Test the 5 volt reference circuit of the right air temperature actuator for a short to voltage, a high resistance, or an open. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 11 |
8 | Test the signal circuit of the right air temperature actuator for a short to ground. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 12 |
9 | Test the signal circuit of the right air temperature actuator for a short to voltage, a high resistance, or an open. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 10 |
10 | Test the low reference circuit of the right air temperature actuator for a high resistance or an open. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 12 |
11 | Inspect for poor connections at the harness connector of the right air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 13 |
12 | Inspect for poor connections at the harness connector of the HVAC control processor. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 14 |
13 |
Important: Perform the recalibration procedure for the right air temperature actuator. Replace the right air temperature actuator. Refer to Air Temperature Actuator Replacement - Right Side . Did you complete the replacement? | -- | Go to Step 15 | -- |
14 |
Important: Perform the recalibration procedure for the HVAC control processor. Replace the HVAC control processor. Refer to HVAC Control Processor Replacement . Did you complete the replacement? | -- | Go to Step 15 | -- |
15 |
Does the DTC reset? | -- | Go to Step 2 | System OK |