Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: Air delivery does not operate correctly. | ||||
1 |
Are any HVAC DTCs present? | -- | Go to the appropriate DTC table for diagnosis | |
2 |
Does the air flow change discharge locations? | -- | ||
3 | Using the scan tool adjust the mode position. Does the air flow change discharge locations? | -- | ||
4 | Inspect the mode actuator and mode valves for binding or mechanical failure. Was a binding condition repaired? | -- | ||
5 | Replace the mode actuator. Refer to Mode Actuator Replacement . Is the repair complete? | -- | -- | |
6 | Replace the instrument panel integration module. Refer to Control Assembly Replacement . Is the repair complete? | -- | -- | |
7 | Confirm that the air delivery system is operating correctly. Is the air delivery system operating correctly? | -- | System OK | -- |