Item Measured | Preset Controls | |||
---|---|---|---|---|
Fan - OFF Temp - 56°C (74°F) Mode - Floor Outside Air OFF Recirc Air OFF A/C Request OFF Rear Defog OFF | Fan - Max Speed Temp - Max Hot Mode - Floor Outside Air ON Recirc Air OFF A/C Request OFF Rear Defog OFF | Fan - Max Speed Temp - Max Cold Mode - Upper Vent Outside Air ON Recirc Air OFF A/C Request ON Rear Defog OFF | Fan - Auto Temp - 56°C (74°F) Mode - Auto Outside Air ON Recirc Air OFF A/C Request OFF Rear Defog OFF | |
Engine Idling/Closed Loop/Park/Doors Closed/Windows Closed/Ambient Air Temp. 22-27°C (70-80°F) | ||||
Outside Air Temperature | 27°C (80°F) | 26°C (79°F) | 27°C (80°F) | 27°C (80°F) |
Inside Air Temperature | 28°C (81°F) | 29°C (82°F) | 26°C (79°F) | 26°C (79°F) |
Upper Outlet Temperature | 17°C (62°F) | 21°C (69°F) | 9°C (49°F) | 19°C (67°F) |
Lower Outlet Temperature | 25°C (75°F) | 51°C (124°F) | 16°C (61°F) | 23°C (73°F) |
Solar Sensor | 231 Counts | 231 Counts | 231 Counts | 231 Counts |
Mix Door Maximum Position | 200 Counts | 200 Counts | 200 Counts | 200 Counts |
Air Mix Door Commanded | 48 Counts | 200 Counts | 48 Counts | 48 Counts |
Air Mix Door Actual | 49 Counts | 200 Counts | 47 Counts | 50 Counts |
Mix Door Minimum Position | 48 Counts | 48 Counts | 48 Counts | 48 Counts |
Blower Motor PWM Speed | 0% | 96% | 96% | 13% |
Mode Selection Position | Floor | Floor | Upper Outlet | Auto |
A/C Request | No | No | Yes | No |
A/C LED ON | OFF | OFF | ON | OFF |
Rear Defog Switch | OFF | OFF | OFF | OFF |
Select Solenoid 1 | ON | ON | OFF | OFF |
Select Solenoid 2 | OFF | OFF | ON | ON |
Select Solenoid 3 | ON | ON | ON | ON |
Select Solenoid 4 | OFF | OFF | OFF | OFF |
Select Solenoid 5 | OFF | OFF | OFF | OFF |