The Outside Air Temperature Sensor is a thermistor that controls signal voltage to the Instrument Panel Integration Module (IPM). The IPM applies voltage on circuit 735. When the sensor is cold, the resistance is high and the IPM will sense a high signal voltage at terminal B1, connector C2. When the sensor warms, resistance is reduced and the signal voltage is pulled low through circuit 61. Signal voltage will vary from 5 V (open circuit) to 0 V (short circuit).
• | The ignition is ON. |
• | Circuit open or shorted. |
• | A blank is displayed on the drivers information center. |
• | A default value of 15°C (59°F) will be used by the IPM to allow operation of the A/C system. |
• | Using a scan tool. |
• | A current DTC will clear when the diagnostic runs and does not fail. |
• | IPM battery voltage is interrupted. |
The numbers below refer to the step numbers on the diagnostic table.
Perform the Body Control Module Diagnostic System Check before continuing with the diagnosis of this DTC.
Ensures that the DTC was not set in error.
This step determines whether the malfunction is in the sensor or if there is an open or a short in a circuit.
This step determines if the IPM is malfunctioning.
The scan tool verifies proper sensor operation. Clear all DTCs after the repair procedures are complete.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Did you perform the IPM/DIM/RIM diagnostic system check? | -- | Go to Step 2 | ||
2 |
Is the voltage within the specified range? | 4.5-5.5 V | Go to Step 3 | Go to Step 4 |
Did the DTC reset? | -- | Go to Step 4 | ||
The ambient air temperature sensor counts increases to 255. Did the ambient air temperature sensor counts decrease the specified value? | 255 counts | Go to Step 5 | Go to Step 6 | |
5 | Replace the sensor. Refer to Ambient Temperature Sensor Replacement in HVAC Systems with A/C-Automatic Is the replacement complete? | -- | Go to Step 7 | -- |
6 | Inspect CKT 61 (YEL) for an open or a short. Did you locate an open or a short? | -- | Go to Step 8 | Go to Step 7 |
Is the replacement complete? | -- | Go to Step 9 | -- | |
8 | Repair the open in CKT 61 (YEL). Is the repair complete? | -- | Go to Step 9 | -- |
Is the A/C system operating normally? | -- | -- |