The Outside Air Temperature Sensor is a thermistor that controls signal voltage to the Instrument Panel Integration Module (IPM). The IPM applies voltage on circuit 735. When the sensor is cold, the resistance is high and the IPM will sense a high signal voltage at terminal B1, connector C2. When the sensor warms, resistance is reduced and the signal voltage is pulled low through circuit 61. Signal voltage will vary from 5 V (open circuit) to 0 V (short circuit).

Conditions for Setting the DTC

    • The ignition is ON.
    • Circuit open or shorted.

Action Taken When the DTC Sets

    • A blank is displayed on the drivers information center.
    • A default value of 15°C (59°F) will be used by the IPM to allow operation of the A/C system.

Conditions for Clearing the MIL/DTC

    • Using a scan tool.
    • A current DTC will clear when the diagnostic runs and does not fail.
    • IPM battery voltage is interrupted.

Test Description

The numbers below refer to the step numbers on the diagnostic table.

  1. Perform the Body Control Module Diagnostic System Check before continuing with the diagnosis of this DTC.

  2. Ensures that the DTC was not set in error.

  3. This step determines whether the malfunction is in the sensor or if there is an open or a short in a circuit.

  4. This step determines if the IPM is malfunctioning.

  5. The scan tool verifies proper sensor operation. Clear all DTCs after the repair procedures are complete.

DTC 1310 Ambient Air Temperature Sensor

Step

Action

Value(s)

Yes

No

1

Did you perform the IPM/DIM/RIM diagnostic system check?

--

Go to Step 2

Go to Diagnostic System Check - Body Control System

2

  1. Turn the ignition ON.
  2. Disconnect the Ambient Air Temperature Sensor.
  3. Measure the voltage between the sensor harness connector terminals A and B.

Is the voltage within the specified range?

4.5-5.5 V

Go to Step 3

Go to Step 4

3

  1. Turn the ignition OFF.
  2. Reconnect the sensor.
  3. Connect the scan tool.
  4. Turn the ignition ON.
  5. Use a scan tool to clear the DTC.
  6. Start the engine.

Did the DTC reset?

--

Go to Step 4

Go to Intermittents and Poor Connections

4

  1. Connect the scan tool.
  2. Select IPM open/short data.
  3. Display the ambient air temperature data.
  4. Start the engine.
  5. Unplug the ambient air temperature sensor.
  6. The ambient air temperature sensor counts increases to 255.

  7. Reconnect the ambient temperature sensor connector.

Did the ambient air temperature sensor counts decrease the specified value?

255  counts

Go to Step 5

Go to Step 6

5

Replace the sensor.

Refer to Ambient Temperature Sensor Replacement in HVAC Systems with A/C-Automatic

Is the replacement complete?

--

Go to Step 7

--

6

Inspect CKT 61 (YEL) for an open or a short.

Did you locate an open or a short?

--

Go to Step 8

Go to Step 7

7

  1. Inspect CKT 735 (LT GRN/BLK) for an open or a short.
  2. If OK, replace the IPM. Refer to Body Control Module Replacement in HVAC Systems with A/C-Automatic.

Is the replacement complete?

--

Go to Step 9

--

8

Repair the open in CKT 61 (YEL).

Is the repair complete?

--

Go to Step 9

--

9

  1. Using a scan tool clear all the DTCs.
  2. Confirm proper operation of the A/C system.

Is the A/C system operating normally?

--

Go to Diagnostic System Check - Body Control System

--