The Inside Air Temperature Sensor is a thermistor that controls signal voltage to the Instrument Panel Integration Module (IPM). The inside air temperature sensor contains an electric fan which pulls the air from the passenger compartment to the sensor. The IPM applies voltage on circuit 734. When the sensor is cold, the resistance is high and the IPM will sense a high signal voltage at terminal B4, connector C2. When the sensor warms, resistance is reduced and the signal voltage is pulled low through circuit 61. Signal voltage will vary from 5 V (open circuit) to 0 V (short circuit).
• | The ignition is ON. |
• | DTC B1310 is not set. |
• | Circuit short or open. |
• | A default value of 24°C (75°F) will be used by the IPM. |
• | The default value allows the system to operate. |
• | Using a Scan tool. |
• | A current DTC will clear when the diagnostic runs and does not fail. |
• | IPM battery voltage is interrupted. |
The numbers below refer to the step numbers on the diagnostic table.
Perform the Body Control Module (BCM) diagnostic system check before continuing with the diagnosis of this DTC.
This step ensures that the DTC was not set in error.
This step determines whether the cause of the malfunction is the sensor or an open or a short in a circuit.
This step determines if the IPM is malfunctioning.
Clear all the DTC's after the repair procedures are complete.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Did you perform the IPM/DIM/RIM diagnostic system check? | -- | Go to Step 2 | ||
2 |
Is the voltage within the specified range? | 4.5-5.5 V | Go to Step 3 | Go to Step 6 |
Did the DTC reset? | -- | Go to Step 4 | ||
Is the in-car air temperature sensor reading the specified value? | 24° Celcius or 75° Farenhiet | Go to Step 7 | Go to Step 5 | |
Is the repair complete? | -- | Go to Step 12 | -- | |
6 | Measure the voltage between sensor terminal A and ground. Is the voltage within the specified range? | 4.5-5.5 V | Go to Step 7 | Go to Step 9 |
7 | Inspect the HVAC sensor DTCs. Are all of the HVAC sensor DTCs present? | -- | Go to Step 8 | Go to Step 11 |
8 |
| -- | Go to Step 11 | Go to Step 12 |
9 | Measure the voltage between IPM terminal B4 and ground. Is the voltage within the specified range? | 4.5-5.5 V | Go to Step 10 | Go to Step 5 |
10 | Repair the open in CKT 734 (DK GRN). Is the repair complete? | -- | Go to Step 13 | -- |
11 | Repair the open in CKT 61 (YEL). Is the repair complete? | -- | Go to Step 13 | -- |
12 | Replace the in-car air temperature sensor. Sunload and Twilight Sentinel Sensor Replacement Is the replacement complete? | -- | Go to Step 13 | -- |
Is the A/C system operating normally? | -- | -- |