The left A/C temperature sensor is a thermistor that controls signal voltage to the Instrument Panel Integration Module (IPM). The IPM applies voltage on circuit 516. When the sensor is cold, the resistance is high and the IPM will sense a high signal voltage at terminal B6, connector C2. When the sensor warms, resistance is reduced and the signal voltage is pulled low through circuit 61. Signal voltage will vary from 5 V (open circuit) to 0 V (short circuit).
• | The ignition is ON. |
• | Circuit open or shorted. |
• | A default value of 128 counts and 24°C (75°F) will be used by the IPM. |
• | The default valve allows the system to operate. |
• | If air delivery is on A/C or bilevel, the air mix one door will cycle between full cold and full hot. |
• | Using a scan tool. |
• | A current DTC will clear when the diagnostic runs and does not fail. |
• | IPM battery voltage is interrupted. |
The numbers below refer to the step numbers on the diagnostic table.
This step determines whether the Body Control Module (BCM) Diagnostic System Check was performed.
This step ensures that the DTC was not set in error.
This step determines whether the cause of the malfunction is the sensor, or an open or a short in a circuit.
The scan tool verifies proper sensor operation. Clear all the DTCs after the repair procedure is complete.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Was the IPM/DIM/RIM diagnostic system check performed? | -- | Go to Step 2 | ||
2 |
Is the voltage within the specified range? | 4.5-5.5 V | Go to Step 3 | Go to Step 4 |
Did DTC reset? | -- | Go to Step 4 | Go to Intermittents and Poor Connections in HVAC Systems with A/C-Automatic | |
Did the LH A/C temperature sensor voltage decrease? | -- | Go to Step 6 | Go to Step 5 | |
5 |
Refer to Air Conditioning (A/C) Temperature Sensor Replacement in HVAC Systems with A/C-Automatic. Is the replacement complete? | -- | Go to Step 9 | -- |
6 | Inspect CK 61 (YEL) for a short . Was an open located? | -- | Go to Step 8 | Go to Step 7 |
7 |
Is the replacement complete? | -- | Go to Step 9 | -- |
8 | Repair the short in CKT 61 (YEL), Is the repair complete? | -- | Go to Step 9 | -- |
Is the A/C system operating normally? | -- | -- |