Tools Required
- Raise the vehicle. Refer to
Lifting and Jacking the Vehicle
.
- Attach the J 22124-91
pressure gage adapter to the air dryer.
- Attach the J 22124-B
pressure gage to the J 22124-91
pressure gage adapter with the toggle valve on the opposite
side of the air compressor. Close the toggle valve.
- Apply air pressure at the schrader valve. Pressurize until the J 22124-B
pressure gage reads
690 kPa (100 psi).
- Inspect the following areas using soap bubbles:
- Lower the vehicle. Refer to
Lifting and Jacking the Vehicle
.