Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: The rear mode air delivery does not operate. | ||||
1 |
Is voltage greater than the specified value? | 10.5 V | Go to Step 2 | Go to Step 6 |
2 | Measure voltage between terminal B of the rear blower switch and ground. Is voltage greater than the specified value? | 10.5 V | Go to Step 3 | Go to Step 6 |
3 |
Is voltage measured greater than the value? | 10.5 V | Go to Step 4 | Go to Step 7 |
4 | Measure the voltage drop between terminal 7 of the rear mode actuator and ground. Is the voltage drop measured near the value? | 0-0.03 V | Go to Step 5 | Go to Step 8 |
5 | Replace the rear mode actuator. Refer to Auxiliary Mode Valve Actuator Replacement . Is the repair complete? | -- | Go to Step 10 | -- |
6 | Inspect CKT 141 (BRN) for an open condition. Is the repair complete? | -- | Go to Step 10 | -- |
7 | Measure voltage between terminal K of the rear blower switch and ground. Is voltage measured greater then the value? | 10.5 V | Go to Step 8 | Go to Step 9 |
8 | Inspect CKT 350 (BLK) for and open. Is the repair complete? | -- | Go to Step 10 | -- |
9 | Replace the rear blower switch. Is the repair complete? | -- | Go to Step 10 | -- |
10 | Confirm proper operation of the rear blower and the rear modes. Is the rear blower and the rear mode systems operating normally? | -- | System OK | -- |