Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Lighting System Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Is the voltage within the specified range? | 10-15 V | Go to Step 3 | Go to Step 5 |
3 | Connect a DMM from the suspect backup lamp connector cavity A (LT GRN) to cavity G (BLK). Is the voltage within specified range? | 10-15 V | Go to Step 4 | Go to Step 6 |
4 | Replace the suspect backup lamp. Refer to Backup Lamp Replacement . Is the backup lamp replacement complete? | -- | Go to Step 7 | -- |
5 | Repair the open in CKT 24 (LT GRN) between S410 and the suspect backup lamp. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | Go to Step 7 | -- |
6 | Repair the open in CKT 850 (BLK) between S413 and the suspect backup lamp. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK. | Go to Step 2 |