Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Lighting Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Does the IP compartment lamp light? | -- | Go to Step 3 | Go to Step 5 |
3 |
Is the resistance less than the specified value? | 0.5 ohms | Go to Step 4 | Go to Step 8 |
4 | Replace the IP compartment lamp switch. Refer to Instrument Panel Compartment Lamp Switch Replacement in Instrument Panel, Gauges and Console. Is the IP compartment lamp switch replacement complete? | -- | Go to Step 11 | -- |
5 |
Is the voltage within the specified range? | 10-15 V | Go to Step 6 | Go to Step 9 |
6 | Connect a DMM from the IP compartment lamp connector cavity B (DK BLU/BLK) to the IP compartment lamp switch connector cavity B (DK BLU/WHT). Is the resistance less than the specified value? | 0.5 ohms | Go to Step 7 | Go to Step 10 |
7 | Replace the IP compartment lamp. Refer to Instrument Panel Storage Compartment Lamp Replacement . Is the IP compartment lamp replacement complete? | -- | Go to Step 11 | -- |
8 | Repair the open in CKT 450 (BLK) between the IP compartment lamp switch and S210. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | Go to Step 11 | -- |
9 | Repair the open in CKT 149 (DK BLU/WHT) between the IP compartment lamp and C308. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | Go to Step 11 | -- |
10 | Repair the open in CKT 148 (DK BLU/BLK) between the IP compartment lamp and the IP compartment lamp switch. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | Go to Step 11 | -- |
11 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK. | Go to Step 2 |