Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Lighting Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Is the voltage within the specified range? | 10-15 V | Go to Step 3 | Go to Step 5 |
3 | Connect a DMM from the vanity lamp connector cavity B (DK BLU/WHT) to cavity A (BLK). Is the voltage within the specified range? | 10-15 V | Go to Step 4 | Go to Step 6 |
4 | Replace the inoperative vanity lamp. Refer to Vanity Mirror Lamp Replacement . Is the vanity lamp replacement complete? | -- | Go to Step 7 | -- |
5 | Repair the open in CKT 149 (DK BLU/WHT) between C310 and the inoperative vanity lamp. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | Go to Step 7 | -- |
6 | Repair the open in CKT 850 (BLK) between C310 and the inoperative vanity lamp. Refer to Wiring Repairs in Wiring Systems. Is the circuit repair complete? | -- | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK. | Go to Step 2 |