Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: One power door lock does not lock and/or unlock. All other door locks operate correctly. | ||||
1 | Did you perform the Power Door Locks System Check ? | -- | Go to Step 2 | |
2 |
Is the voltage within the specified range for both measurements? | 10-15 V | Go to Step 3 | Go to Step 4 |
3 | Replace the power door lock actuator at the malfunctioning door. Refer to Front Side Door Latch Replacement or Rear Side Door Latch Replacement . Is the repair complete? | -- | -- | |
4 |
Is the resistance within the specified range? | 0-5 ohms | Go to Step 6 | Go to Step 5 |
5 | Repair the open in CKT 294. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 | Using a DMM, measure the resistance between door lock actuator harness connector C2 terminal B and door module harness connector C2 terminal H (LH doors) or M (RH doors). Is the resistance within the specified range? | 0-5 ohms | Go to Step 8 | Go to Step 7 |
7 | Repair the open in CKT 295. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
8 | Replace the door module at the malfunctioning door. Refer to Door Control Module Replacement . Is the replacement complete? | -- | -- |