The LF/driver inflatable restraint side impact inflator module deployment loop is a 2 wire circuit. When you first turn ON the ignition, the inflatable restraint sensing and diagnostic module (SDM) performs tests to diagnose critical malfunctions within itself. Then the SDM performs the following continuous diagnostic tests on the deployment loops:
• | Deployment loop voltage out of range test |
• | Deployment loop resistance measurement test |
If the voltage out of range test detects a short to voltage condition, the resistance measurement test for that deployment loop will not be performed.
Deployment loop voltage out of range test - Ignition 1 voltage is within the normal operating voltage range.
Deployment loop resistance measurement test:
• | Ignition 1 voltage is within the normal operating voltage range. |
• | LF side deployment loop is not shorted to voltage. |
• | Deployment loop voltage out of range test - LF side high terminal is greater than 6 volts for 500 milliseconds. |
• | Deployment loop resistance measurement test - LF side high terminal is less than 2.4 volts and LF side deployment loop resistance is less than 6 ohms for 500 milliseconds. |
The SDM commands ON the AIR BAG warning lamp via Class 2 serial data.
• | LF side high terminal is less than or equal to 6 volts for 500 milliseconds. |
• | LF side high terminal is greater than or equal to 2.4 volts and LF side deployment loop resistance is less than 6 ohms for 500 milliseconds. |
• | You can issue a CLEAR CODES command |
• | A history DTC will clear once 255 malfunction free ignition cycles have occurred |
The following can cause an intermittent condition:
• | A short to ground or to voltage on either of the two sides of the deployment loop circuit can cause a intermittent condition. |
• | Inspect the LF side high and LF side low circuits carefully for cutting or chafing or any type of wire damage. |
• | Wiring damage requires replacement of the inflatable restraint side impact inflator module harness. |
If any of the above conditions are found refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
The number(s) below refer to the step number(s) on the diagnostic table.
This step checks the LF/driver side air bag in-line connector.
This step checks to see if there is a malfunctioning LF side air bag (inflatable restraint side impact inflator module).
This step checks to see if there is a short to ground in the LF side high deployment circuit.
This step checks to see if there is a short to ground in the LF side low deployment circuit.
This step checks to see if there is a short to voltage in the LF side high deployment circuit.
This step determines if there is a short to voltage in the LF side low deployment circuit or if there is a malfunctioning SDM.
This step clears all SIR DTC's.
Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Diagnostic System Check? | -- | ||||||||
Does connector exhibits any signs of corrosion, terminal damaged, or poor connections? | -- | |||||||||
3 |
Did you complete the replacement? | -- | -- | |||||||
4 |
Does the scan tool indicate that this DTC is current? | -- | Go to Diagnostic Aids | |||||||
Does the scan tool indicate that this DTC is current? | -- | |||||||||
6 |
Did you complete the replacement? | -- | -- | |||||||
Does the resistance measure less than the specified value? | OL | |||||||||
8 | Locate and repair the short to ground in LF side high deployment circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |||||||
Use the J 39200 and measure the resistance between the SDM wiring harness connector LF side low deployment circuit terminal and a known good ground. Does the resistance measure less than the specified value? | OL | |||||||||
10 | Locate and repair the short to ground in LF side low deployment circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |||||||
Does the voltage measure less than the specified value? | 1 V | |||||||||
12 | Locate and repair the short to voltage in LF side high deployment circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |||||||
Use the J 39200 and measure voltage between the SDM wiring harness connector LF side low deployment circuit terminal and a known good ground. Does the voltage measure less than the specified value? | 1 V | |||||||||
14 | Locate and repair the short to voltage in LF side low deployment circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |||||||
15 | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Did you complete the replacement? | -- | -- | |||||||
Did you complete the action? | -- | -- |