Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Important: A short to ground will cause a open fuse(s). Before performing this diagnostic procedure, inspect the fuse(s) for an open. | ||||
1 |
Is voltage measured within the specified range? | 9.6 V or Greater | Go to Step 2 | Go to Battery Load Test . |
2 | Measure voltage drop with a DMM between the negative battery terminal and the engine block while attempting to crank the engine. Is the voltage drop within the specified range? | 0.5 V or Less | Go to Step 3 | Go to Step 4 |
3 | Measure voltage between the positive battery terminal and the starter solenoid terminal B while attempting to crank the engine. Is voltage measured within the specified range? | 0.5 V or Less | Go to Step 5 | |
4 | Clean the terminals or replace the negative battery cable between the battery and the engine block. Is repair complete? | -- | System OK | -- |
5 | Clean the terminals or replace the positive battery cable between the battery and the starter motor. Is repair complete? | -- | System OK | -- |