Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Important: A short to ground will cause an open fuse(s). Before performing this diagnostic procedure, inspect the fuse(s) for an open. | ||||
1 |
Does the test lamp light? | -- | Go to Step 2 | Go to Step 3 |
2 |
Is the measured resistance within the specified range? | 0-2 ohms | Go to Step 4 | Go to Step 5 |
3 | Repair the open in CKT 151 between the panel dimmer switch and ground splice pack G202. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
4 |
Do the IP lamps remain lit? | -- | Go to Step 6 | Go to Step 7 |
5 | Repair the open in CKT 44 between the lamp dimmer module and the panel dimmer switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 | Replace the lamp dimmer module. Is the repair complete? | -- | -- | |
7 | Replace the panel dimmer switch. Is the repair complete? | -- | -- |