J 39400-A Electronic Halogen Leak Detector
Notice: Do not mix refrigerant oils. Use of incorrect refrigerant oil will cause compressor failure.
The CVC compressor uses a low viscosity refrigerant oil, GM P/N 12378526 (Canadian P/N 88900060).Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Install the condenser (2) to the radiator (1)
Tighten
Tighten the condenser bolts to 10 N·m (89 lb in).
Tighten
Tighten the nut to 25 N·m (18 lb ft).
Tighten
Tighten the bolt to 25 N·m (18 lb ft).