Removal Procedure
- Remove the instrument
panel. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gauges and Console.
- Remove the bolts (4) that retain inflatable restraint IP module
to the instrument panel.
- Remove the nuts (5) from the studs (1) on the IP module.
- Remove the inflatable restraint module (2) from the instrument
panel (3).
- Fully deploy the module before disposal. If the module was replaced
under warranty, fully deploy and dispose of the module after the required
retention period. Refer to
Inflator Module Handling, Shipping, and Scrapping
.
Installation Procedure
- Install the inflatable
restraint module (2) to the instrument panel (3).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the bolts (4) that retain inflatable restraint module to the
instrument panel.
Tighten
Tighten the bolts to 8 N·m(71 lb in).
- Install the nuts (5) to the studs (1) to retain the IP module
to the instrument panel.
Tighten
Tighten the nuts to 8 N·m(71 lb in).
- Install the instrument panel. Refer to
Instrument Panel Carrier Replacement