Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Was the Power Door Locks System Check performed? | -- | Go to Step 2 | Refer to Power Door Locks System Check | ||||||||
2 |
Are one or more of the above DTCs set as a current code? | -- | Go to Diagnostic System Check - Body Control System in Body Control System | Go to Step 3 | ||||||||
3 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 5 | ||||||||
4 | Connect a fused jumper wire between terminal D, CKT 840 (ORN) and terminal A, CKT 195 (LT BLU) of the endgate lock cylinder connector. Do the doors LOCK? | -- | Go to Step 6 | Go to Step 7 | ||||||||
5 | Repair an open in CKT 840 (ORN). Is the repair complete? | -- | Refer to Power Door Locks System Check | -- | ||||||||
6 | Connect a fused jumper wire between terminal D, CKT 840 (ORN) and terminal B, CKT 194 (WHT) of the endgate lock cylinder connector. Do the doors UNLOCK? | -- | Go to Step 8 | Go to Step 9 | ||||||||
7 | Repair the open in CKT 195 (LT BLU). Is the repair complete? | -- | Refer to Power Door Locks System Check | -- | ||||||||
8 | Replace the endgate lock cylinder switch. Is the repair complete? | -- | Refer to Power Door Locks System Check | -- | ||||||||
9 | Repair the open in CKT 194 (WHT). Is the repair complete? | -- | Refer to Power Door Locks System Check | -- |