GM Service Manual Online
For 1990-2009 cars only

Step

Action

Value(s)

Yes

No

1

Was the Power Windows System Check performed?

--

Go to Step 2

Refer to Power Windows System Check

2

  1. Access the RH door lock and side window switch.
  2. Turn the ignition switch to the RUN position.
  3. Connect a J 39200 (DMM) to CKT 1001 (DK GRN), terminal L at the RH door lock and side window switch connector C1 and ground.
  4. Ensure that connector C1 remains connected.
  5. Test for voltage.

Is ignition voltage present?

IGN+

Go to Step 4

Go to Step 3

3

Repair the open or high resistance in CKT 1001 (DK GRN) between the power windows circuit breaker and the RH door lock and side window switch.

Is the repair complete?

--

Refer to Power Windows System Check

--

4

  1. Turn the ignition switch to the RUN position.
  2. Connect a J 39200 DMM to CKT 1001 (DK GRN), terminal L at the RH door lock and side window switch connector C1 and CKT 1850 (BLK), terminal C at the RH door lock and side window switch connector C2.
  3. Test for voltage.

Is ignition voltage present?

IGN+

Go to Step 6

Go to Step 5

5

Repair the open or high resistance in CKT 1850 (BLK) between the RH door lock and side window switch connector C2 and G202.

Is the repair complete?

--

Refer to Power Windows System Check

--

6

  1. Turn the ignition switch to the RUN position.
  2. Connect a J 39200 DMM to CKT 164 (DK BLU), terminal B and CKT 165 (BRN), terminal D at the RH door lock and side window switch connector C2.
  3. Ensure that connector C2 remains connected.
  4. Operate the RH door lock and side window switch in the UP/DOWN position.
  5. Test for voltage.
  6. Connect the J 39200 DMM to CKT 166 (LT BLU), terminal A and CKT 167 (TAN), terminal E at the RH door lock and side window switch connector C2.
  7. Ensure that connector C2 remains connected.
  8. Operate the RH door lock and side window switch in the UP/DOWN position.
  9. Test for voltage.

Is ignition voltage present?

IGN+

Go to Step 8

Go to Step 7

7

Replace the RH door lock and side window switch.

Is the repair complete?

--

Refer to Power Windows System Check

--

8

  1. Turn the ignition switch to the RUN position.
  2. Connect a J 39200 DMM to CKT 164 (DK BLU), terminal B connector C2 at the RH front side window regulator motor and CKT 165 (BRN), terminal D at the RH door lock and side window switch connector C2.
  3. Ensure that the connector C2 remains connected.
  4. Operate the RH door lock and side window switch in the UP position.
  5. Test for voltage.

Is ignition voltage present?

IGN+

Go to Step 10

Go to Step 9

9

Repair the open or high resistance in CKT 164 (DK BLU) between the RH door lock and side window switch and the RH side window regulator motor.

Is the RH side window regulator now operational?

--

Go to Step 15

Go to Step 10

10

  1. Turn the ignition switch to the RUN position.
  2. Connect a J 39200 DMM to CKT 164 (DK BLU), terminal B at the RH door lock and side window switch connector C2 and CKT 165 (BRN), terminal B at the RH side window regulator motor connector C1.
  3. Ensure that the connectors remain connected.
  4. Operate the RH side window regulator switch in the DOWN position.
  5. Test for voltage.

Is ignition voltage present?

IGN+

Go to Step 12

Go to Step 11

11

Repair the open or high resistance in CKT 165 (BRN) between the RH door lock and side window switch and the RH side window regulator motor.

Is the RH side window regulator now operational?

--

Go to Step 15

Go to Step 12

12

Inspect for a poor connection at the RH side window regulator motor.

Is the connection OK?

--

Go to Step 14

Go to Step 13

13

Repair the connection as necessary.

Is the RH side window regulator now operational?

--

Go to Step 15

Refer to Power Windows System Check

14

Replace the RH side window regulator motor.

Is the RH side window regulator now operational?

--

Go to Step 15

Refer to Power Windows System Check

15

  1. Access the LH door lock and side window switch.
  2. Turn the ignition switch to the RUN position.
  3. Connect a J 39200 DMM to CKT 166 (LT BLU), terminal J at the LH door lock and side window switch connector C1and ground.
  4. Ensure that the LH door lock and side window switch connector C1 remains connected.
  5. Operate the LH side window regulator motor at the RH door lock and side window switch in the UP position.
  6. Test for voltage.

Is ignition voltage present?

IGN+

Go to Step 17

Go to Step 16

16

Repair the open or high resistance in CKT 166 (LT BLU) between the RH door lock and side window switch and the LH door lock and side window switch connector.

Is the repair complete?

--

Refer to Power Windows System Check

--

17

  1. Turn the ignition switch to the RUN position.
  2. Connect a J 39200 DMM to CKT 167 (TAN), terminal L at the LH door lock and side window switch connector C1 and ground.
  3. Ensure that the LH door lock and side window switch connector C1 remains connected.
  4. Operate the LH side window regulator motor at the RH door lock and side window switch in the DOWN position.
  5. Test for voltage.

Is ignition voltage present?

IGN+

Go to Step 19

Go to Step 18

18

Repair the open or high resistance in CKT 167 (TAN) between the RH door lock and side window switch and the LH door lock and side window switch connector.

Is the repair complete?

--

Refer to Power Windows System Check

--

19

  1. Turn the ignition switch to the RUN position.
  2. Connect a J 39200 DMM to CKT 667 (BRN), terminal K and CKT 666 (DK BLU), terminal G at the LH door lock and side window switch connector C1.
  3. Ensure that connector C1 remains connected.
  4. Operate the LH side window regulator motor from the RH door lock and side window switch in the UP/DOWN position.
  5. Test for voltage.

Is ignition voltage present?

IGN+

Go to Step 23

Go to Step 20

20

Inspect for a poor connection at the LH door lock and side window switch.

Is the connection OK?

--

Go to Step 22

Go to Step 21

21

Repair the connection as necessary.

Is the repair complete?

--

Refer to Power Windows System Check

--

22

Replace the LH door lock and side window switch.

Is the repair complete?

--

Refer to Power Windows System Check

--

23

  1. Turn the ignition switch to the RUN position.
  2. Connect a J 39200 DMM to CKT 667 (BRN), terminal K at the LH door lock and side window switch connector C1 and CKT 666 (DK BLU), terminal C at the LH window regulator motor connector.
  3. Ensure that the connectors remain connected.
  4. Operate the LH side window regulator motor from the RH door lock and side window switch in the UP position.
  5. Test for voltage.

Is Ignition voltage present?

IGN+

Go to Step 25

Go to Step 24

24

Repair the open or high resistance in CKT 666 (DK BLU) between the LH door lock and side window switch terminal G and the LH side window regulator motor terminal C.

Is the repair complete?

--

Refer to Power Windows System Check

--

25

  1. Turn the ignition switch to the RUN position.
  2. Connect a J 39200 DMM to CKT 667 (BRN), terminal B and CKT 666 (DK BLU), terminal C at the LH side window regulator motor connector.
  3. Ensure that the connector remains connected.
  4. Operate the LH side window regulator motor from the RH door lock and side window switch in the DOWN position.
  5. Test for voltage.

Is Ignition voltage present?

IGN+

Go to Step 27

Go to Step 26

26

Repair the open or high resistance in CKT 667 (BRN) between the LH door lock and side window switch connector C1 terminal K and the LH side window regulator motor terminal B.

Is the repair complete?

--

Refer to Power Windows System Check

--

27

Inspect for a poor connection at the LH side window regulator motor.

Is the connection OK?

--

Go to Step 29

Go to Step 28

28

Repair the connection as necessary.

Is the repair complete?

--

Refer to Power Windows System Check

--

29

Replace the LH side window regulator motor.

Is the repair complete?

--

Refer to Power Windows System Check

--