The outside air temperature sensor is a thermistor used to control the signal voltage in the electronic climate control module. The electronic climate control module supplies a reference voltage (about 5 volts) on CKT 636 (DK GRN/WHT) to the sensor. When the outside (ambient) air temperature is cold, the thermistor resistance is high. Therefore, the electronic climate control module will receive a high voltage input. If the outside air temperature is hot, the thermistor resistance is low. The electronic climate control module will receive a low signal voltage input. Refer to Sensor Resistance Table .
When the ignition switch is in the ON position, the electronic climate control module will detect this DTC any time CKT 636 (DK GRN/WHT) is at or near zero voltage.
The electronic climate control module will use a default value of 26°F (or 168) A/D counts until the fault is cleared.
This fault will clear as soon as the fault goes away or has been repaired. The system will then return to normal operation. History DTCs can only be cleared by removing and restoring B+ or by using the scan tool.
Visually inspect the sensor connector and harness for corrosion and damage. The resistance value of the sensor must be witin 300 - 170,000 ohms. If resistance is not within specifications, replace the sensor.
The numbers below refer to the step numbers on the diagnostic table.
This step measures the resistance of the outside (ambient) air temperature sensor.
This step inspects for a short to ground in CKT 636 (DK GRN/WHT).
This step inspects for intermittents and tests for a malfunctioning electronic climate control module
This step repairs the short to ground in CKT 636 (DK GRN/WHT).
This step replaces a defective outside (ambient) air temperature sensor.
This step replaces a defective electronic climate control module.
Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
Tools Required
| ||||||||
1 | Was the Diagnostic System Check performed? | -- | Go to Step 2 | Go to Diagnostic System Check | ||||
Is the resistance within the range specified in the table? | -- | Go to Step 3 | Go to Step 6 | |||||
Is continuity present? | -- | Go to Step 5 | Go to Step 4 | |||||
Does the DTC reset? | -- | Go to Step 7 | Go to Intermittents and Poor Connections Diagnosis in Wiring Systems | |||||
Repair the short to ground in CKT 636 (DK GRN/WHT). Is the repair complete? | -- | Go to Diagnostic System Check | -- | |||||
Replace the outside air temperature sensor. Is the replacement complete? | -- | Go to Diagnostic System Check | -- | |||||
Replace the electronic climate control module. Is the replacement complete? | -- | Go to Diagnostic System Check | -- |