Step
| Action
| Value(s)
| Yes
| No
|
1
| Did you complete the HVAC Blower Control System Check?
| --
| Go to
Step 2
| Go to
HVAC Blower Controls System Check
|
2
|
- Turn the ignition switch to ON.
- Turn the mode selector to VENT.
- Disconnect the blower resistor connector.
- Turn the blower switch to 3.
- Connect the fused jumper between terminal B and terminal C
of the blower resistor harness connector.
Does the blower motor operate?
| --
| Go to
Step 3
| Go to
Step 4
|
3
| Replace the blower resistor.
Did you complete the repair?
| --
| Go to
HVAC Blower Controls System Check
| --
|
4
|
- Reconnect the blower motor resistor.
- Disconnect the heater-A/C and rear defogger control assembly connector C2.
- Connect the fused jumper between terminal C of the heater-A/C
and rear defogger control assembly harness connector C2 and ground.
Does the blower motor operate?
| --
| Go to
Step 5
| Go to
Step 6
|
5
| Replace the blower switch.
Did you complete the repair?
| --
| Go to
HVAC Blower Controls System Check
| --
|
6
| Repair the open in CKT 72 between the blower resistor
and the blower switch. Refer to
Wiring Repairs
in Wiring Systems.
Did you complete the repair?
| --
| Go to
HVAC Blower Controls System Check
| --
|