Tools Required
J 5403 Snap Ring
Pliers
- Coat the O-rings with
525 viscosity refrigeration oil.
- Using thumb pressure, push the O-rings in place.
Important: Ensure that the retaining ring is properly seated in the ring groove.
- Using the J 5403
, install the valve retaining ring with the high point of the curved sides
against the valve housing.
- Evacuate the system. Recharge the system.
- Perform a leak test. Refer to
Compressor Leak Testing
.