Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the blower motor operate? | -- | Go to Step 2 | Go to Step 3 |
2 | Replace the blower switch. Refer to Blower Switch Replacement in Heating and Ventilation (Non-AC). Does the symptom persist? | -- | -- | System OK |
3 | Repair the open in CKT 52 between S124 and the heater-A/C and rear defogger control assembly. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | System OK | -- |