Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 |
Is the airflow high? | -- | Go to Step 2 | Go to Step 20 | ||||||||
2 | Inspect the blower speeds for a change in the airflow. Does the speed of the airflow change? | -- | Go to Step 3 | |||||||||
3 |
Caution: The cooling system is pressurized when hot. Is the heater temperature low according to the table? | -- | Go to Step 5 | Go to Step 4 | ||||||||
4 |
Does the condition persist? | -- | Go to Step 5 | System OK | ||||||||
5 |
Does the temperature valve appear to be operating? | -- | Go to Step 6 | Go to Step 17 | ||||||||
6 | Verify the temperature valve operation. Is the temperature valve operating? | -- | Go to Step 8 | Go to Step 7 | ||||||||
7 | Inspect for the following conditions. Repair the components as needed:
Does the condition persist? | -- | Go to Step 8 | System OK | ||||||||
8 |
Are both hoses warm? | -- | Go to Step 9 | Go to Step 12 | ||||||||
9 | Inspect the thermostat for the following conditions:
Is the installation OK? | -- | Go to Step 10 | Go to Step 11 | ||||||||
10 | Replace the thermostat. Refer to Engine Coolant Thermostat Replacement in Engine Cooling. Is the repair complete? | -- | System OK | -- | ||||||||
11 |
Is the repair complete? | -- | System OK | -- | ||||||||
12 | The outlet hose is hot and the inlet hose is warm.
Are the hoses installed in reverse? | -- | Go to Step 13 | Go to Step 14 | ||||||||
13 |
Does the condition persist? | -- | Go to Step 14 | System OK | ||||||||
14 |
Are both hoses warm? | -- | Go to Step 15 | Go to Step 16 | ||||||||
15 | Replace the heater core. Refer to Heater Core Replacement . Is the repair complete? | -- | System OK | -- | ||||||||
16 | Is the inlet hose hot and the outlet hose warm? | -- | System OK | -- | ||||||||
17 | Inspect the connection on the temperature valve actuator. Is the temperature valve actuator connected? | -- | Go to Step 19 | Go to Step 18 | ||||||||
18 |
Is the system operating properly? | -- | System OK | -- | ||||||||
19 |
Is the system operating properly? | -- | System OK | -- | ||||||||
20 | The airflow is low or nonexistent. Perform the HVAC functional inspection. Refer to Function Test . Does the condition persist? | -- | Go to Step 21 | System OK | ||||||||
21 | Inspect the airflow out of the followin outlets:
Is the airflow out of the defroster outlets or the vent outlets high? | -- | Go to Step 22 | Go to Step 23 | ||||||||
22 |
Is the repair complete? | -- | System OK | -- | ||||||||
23 | The airflow out of the defroster outlets or the vent outlets is low or nonexistent.
Is the defroster airflow OK? | -- | Go to Step 24 | Go to Step 25 | ||||||||
24 |
Does the system operate properly? | -- | System OK | -- | ||||||||
25 | Inspect the blower speeds for airflow changes. Are the speed changes OK? | -- | Go to Step 26 | |||||||||
26 | Inspect the system for obstructions at the blower inlet and the plenum. Did you find any obstructions? | -- | Go to Step 27 | Go to Step 28 | ||||||||
27 | Remove the obstructions as needed. Does the system operate properly? | -- | System OK | -- | ||||||||
28 |
Did a change in the airflow occur? | -- | Go to Step 29 | Go to Step 30 | ||||||||
29 |
Does the system operate properly? | -- | System OK | -- | ||||||||
30 |
Does the system operate properly? | -- | System OK | -- |
Ambient Air Temperature | Heater Air Temperature |
---|---|
-18°C (0°F) | 54°C (130°F) |
-4°C (25°F) | 59°C (139°F) |
10°C (50°F) | 64°C (147°F) |
24°C (75°F) | 68°C (155°F) |