Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Important: A short to ground will cause an open fuse(s). Before performing this diagnostic procedure,inspect the fuse(s) for an open. | ||||
1 | Did you perform the remote keyless entry system check? | -- | Go to Step 2 | |
2 |
Does the test light flash? | -- | Go to Step 3 | Go to Step 5 |
3 |
Does the test light flash? | -- | Go to Step 4 | Go to Step 5 |
4 |
Does the test light flash? | -- | Go to Step 6 | Go to Step 7 |
5 | Replace the remote control door lock receiver. Refer to Receiver Replacement . Did you complete the repair? | -- | -- | |
6 |
Does the test light flash? | -- | Go to Step 8 | Go to Step 9 |
7 | Repair an open in CKT 694 between the receiver connector terminal A and the motor connector terminal A. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
8 | Replace the LF door lock actuator. Refer to Door Lock Replacement in Doors. Did you complete the repair? | -- | -- | |
9 | Repair an open in CKT 295 between the motor connector terminal B and S248. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- |