Compressor Control Switches Install V5 - Conventional Mount
Tools Required
J 5403 Snap Ring Pliers
- Inspect the switch cavity and the O-ring
groove in the rear head for dirt or foreign material.
Clean the cavity and groove as necessary.
- Coat the new O-ring using clean 525 viscosity refrigerant oil.
- Install the O-ring into the groove in the switch cavity.
- Lubricate the switch housing using clean 525 viscosity refrigerant
oil.
- Carefully insert the switch (3 or 4) into the switch cavity
until the switch bottoms in the cavity.
- Using the J 5403
, install
the switch retaining ring with the high point of the curved sides adjacent
to the switch housing.
- Ensure that the retaining ring is seated in the retaining ring
groove in the switch cavity.
- Evacuate and recharge the system.
- Perform a leak test. Refer to
Compressor Leak Testing
.